400Hz AC ANALOG PANEL LOAD BANKS
Advantages
- Simple operation suitable for non-trained operators and personnel; no maintenance required
- Suitable for workshop or airside operation; silent unit rated at < 70 dB(A) at 7m / 23Ft
- Environmental operating temperature from -20 ºC to 55 ºC / -4 ºF to 122 ºF
- Cant protection – load bank works only when positioned on flat horizontal surface
- Phase detection and rotation indicator – ABC availability, sequence of three-phase voltage
- Fine load regulation knob as standard for complete series of 400 Hz AC load banks
- 400 Hz 6-Pole receptacle in accordance with NATO & MIL-C-81790 specification
- Equipped with 28 V DC control circuit for E&F and applicable bypass interlock circuit
- Housing made of non-corrosive parts with component quality control by the manufacturer
- High reliability with multiple thermal protection – extremely resistant to high temperature
- Extra safety and isolated jack sockets for connecting external voltage measuring device
- Short worldwide delivery period with tracking feature and insurance for all products
- Spare parts availability and accurate on-time deliveries by appointed courier
- Transport casing with pull up handle as standard for every load bank manufactured
- 2 years full warranty with extension option for all DEKAL load banks
- CE certification – health, safety, and environmental protection standards
- Made for GPU’s testing procedure according to ISO 6858, DFS 400, ARP 5015
- Classification CE marking, DIN, VDE, IEC, IP 21 protection rate level
- Customs classification Harmonized System tariff code HS: 8516808000
Select an available model:
TECHNICAL SPECIFICATION | ALB-45AP |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 48 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 5 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW |
FORCED AIR COOLING [m³/min & CFM] | 44.10 m³/min – 1560 CFM |
INDICATIONS | |
---|---|
ANALOG VOLT METER ANALOG AMPERE METER ANALOG FREQUENCY METER | VOLT METER – MOVING IRON CLASS 1.5 AMPERE METER – MOVING IRON CLASS 1.5 FREQUENCY METER – MOVING IRON CLASS 0.5 |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 → 100% 🕑 30 seconds; HOLD at 100% 🕑 5 minutes; LOAD decrease from 100 → 0% 🕑 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 → 100% 🕑 30 seconds; HOLD at 100% 🕑 45 minutes; LOAD decrease from 100 → 0% 🕑 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 25 23.6 x 9.05 x 24.8 / 55 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | FINE POWDER COATING STRUCTURE DRYLAC® 29_80081 / ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|
TECHNICAL SPECIFICATION | ALB-80AP |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 80 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 9 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW 48 – 56 kW 56 – 64 kW 64 – 72 kW 72 – 80 kW |
FORCED AIR COOLING [m³/min & CFM] | 66.15 m³/min – 2340 CFM |
INDICATIONS | |
---|---|
ANALOG VOLT METER ANALOG AMPERE METER ANALOG FREQUENCY METER | VOLT METER – MOVING IRON CLASS 1.5 AMPERE METER – MOVING IRON CLASS 1.5 FREQUENCY METER – MOVING IRON CLASS 0.5 |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 → 100% 🕒 30 seconds; HOLD at 100% 🕒 5 minutes; LOAD decrease from 100 → 0% 🕒 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 → 100% 🕒 30 seconds; HOLD at 100% 🕒 45 minutes; LOAD decrease from 100 → 0% 🕒 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 27 23.6 x 9.05 x 24.8 / 59 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | FINE POWDER COATING STRUCTURE DRYLAC® 29_80081 / ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|
TECHNICAL SPECIFICATION | ALB-100AP |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 104 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 12 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW 48 – 56 kW 56 – 64 kW 64 – 72 kW 72 – 80 kW 80 – 88 kW 88 – 96 kW 96 – 104 kW |
FORCED AIR COOLING [m³/min & CFM] | 88.20 m³/min – 3120 CFM |
INDICATIONS | |
---|---|
ANALOG VOLT METER ANALOG AMPERE METER ANALOG FREQUENCY METER | VOLT METER – MOVING IRON CLASS 1.5 AMPERE METER – MOVING IRON CLASS 1.5 FREQUENCY METER – MOVING IRON CLASS 0.5 |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 → 100% 🕑 30 seconds; HOLD at 100% 🕑 5 minutes; LOAD decrease from 100 → 0% 🕑 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 → 100% 🕑 30 seconds; HOLD at 100% 🕑 45 minutes; LOAD decrease from 100 → 0% 🕑 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 30 23.6 x 9.05 x 24.8 / 66 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | FINE POWDER COATING STRUCTURE DRYLAC® 29_80081 / ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|
TECHNICAL SPECIFICATION | ALB-120AP |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 120 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 14 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW 48 – 56 kW 56 – 64 kW 64 – 72 kW 72 – 80 kW 80 – 88 kW 88 – 96 kW 96 – 104 kW 104 – 112 kW 112 – 120 kW |
FORCED AIR COOLING [m³/min & CFM] | 88.20 m³/min – 3120 CFM |
INDICATIONS | |
---|---|
ANALOG VOLT METER ANALOG AMPERE METER ANALOG FREQUENCY METER | VOLT METER – MOVING IRON CLASS 1.5 AMPERE METER – MOVING IRON CLASS 1.5 FREQUENCY METER – MOVING IRON CLASS 0.5 |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 → 100% 🕒 30 seconds; HOLD at 100% 🕒 5 minutes; LOAD decrease from 100 → 0% 🕒 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 → 100% 🕒 30 seconds; HOLD at 100% 🕒 45 minutes; LOAD decrease from 100 → 0% 🕒 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 33 23.6 x 9.05 x 24.8 / 73 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | FINE POWDER COATING STRUCTURE DRYLAC® 29_80081 / ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|
TECHNICAL SPECIFICATION | ALB-140AP |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 144 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 17 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW 48 – 56 kW 56 – 64 kW 64 – 72 kW 72 – 80 kW 80 – 88 kW 88 – 96 kW 96 – 104 kW 104 – 112 kW 112 – 120 kW 120 – 128 kW 128 – 136 kW 136 – 144 kW |
FORCED AIR COOLING [m³/min & CFM] | 88.20 m³/min – 3120 CFM |
INDICATIONS | |
---|---|
ANALOG VOLT METER ANALOG AMPERE METER ANALOG FREQUENCY METER | VOLT METER – MOVING IRON CLASS 1.5 AMPERE METER – MOVING IRON CLASS 1.5 FREQUENCY METER – MOVING IRON CLASS 0.5 |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 → 100% 🕒 30 seconds; HOLD at 100% 🕒 5 minutes; LOAD decrease from 100 → 0% 🕒 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 → 100% 🕒 30 seconds; HOLD at 100% 🕒 45 minutes; LOAD decrease from 100 → 0% 🕒 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 35 23.6 x 9.05 x 24.8 / 77 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | FINE POWDER COATING STRUCTURE DRYLAC® 29_80081 / ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|