CABLE / PLUG TEST BOX 28.5 V DC
TECHNICAL SPECIFICATION | ALB-140D + EP20 |
---|---|
VOLTAGE [V] | 115 /200 VAC ± 10 % |
FREQUENCY [Hz] | 400 Hz ± 10 % |
LOAD / POWER [kW / kVA] [cosφ=1] | 144 kW ± 10 % |
3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS : ±0.5% S ACC. IEC 62053-22 2003 | V / A / Hz / cosφ=1 / kW / kVA |
CONNECTION TO PC ( LAN CABLE & SOFTWARE INCL.) | LAN+USB+WiFi |
LOAD TEST PROPOSAL FOR GPU TESTING | LOAD raising within 30 sec. from 0 to 100%
LOAD, HOLD on 100% LOAD for 5 min LOAD
decreasing within 10 min from
100 to 0% LOAD |
LOAD TEST PROPOSAL
FOR ENGINE DECARBONISING | LOAD raising within 30 sec. from 0 to 100%
LOAD, HOLD on 100% LOAD for 45 min
LOAD decreasing within 15 min from
100 to 0% LOAD |
COOLING – FORCED [m³/min] | 88,20 |
EP10 or EP20 OPTION | |
---|---|
ADDITIONAL EXTERNAL POWER SUPPLY EP-10 | 110 V AC / 60 Hz ± 20 % |
ADDITIONAL EXTERNAL POWER SUPPLY EP-20 | 230 V AC / 50 Hz ± 20 % |
MAINS CABLE INCL. | 2,5 m |
SWITCHING TIME BETWEEN GPU & MAINS POWER SUPPLY | < 20 ms |
NORMS | |
---|---|
STANDARDS | ISO 6858, DSF 400, ARP 5015 |
CLASIFICATION | CE marking, DIN, VDE, IEC |
ENVIROMENT | |
---|---|
OPERATING TEMPERATURE | -20 ºC to 55 ºC |
MAXIMUM ALTITUDE | 1000 m (w/o Downgrading), max.2000m |
RELATIVE HUMIDITY | 0% – 85% (w/o Condensation) |
DEGREE OF PROTECTION | IP 21 |
DIMENSIONS [L x B x H] / [kg] | 630 x 230 x 630 / 40 |
PAINTING | POWDER COATING FINE STRUCTURE
71319 IGP / Swiss quality |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|